Gas and fire protection for heating rooms and building utility rooms
FIRE AND GAS SECURITY FOR HEATING CENTERS AND TECHNICAL ROOMS IN BUILDINGS
The system for detecting toxic or explosive gas leaks in the technical rooms of residential, tertiary and industrial buildings is based on microprocessor control units, industrial sensors with IP44 and IP55 protection, and gas solenoid valves with manual reset.
The probes with IP55 protection degree are realized with microprocessor technology that assures the diagnostic and automatic calibration functions; they automatically adapt to every kind of environment, avoiding the occurrence of false alarms following anomalous events.
The control units, in execution for DIN bar mounting or in front of the panel, mount a microprocessor able to manage up to 4 probes and to realize system diagnosis functions with status signalling and solenoid valve control. In particular, 2 - 3 alarm levels are available for each model of control unit.
The 1PE3 2004 electronic control unit accepts signals from smoke and temperature probes to create fire-fighting systems; self-powered indoor and outdoor sirens and resettable buttons complete the fire-fighting system.
Perry-1EVEV008Elettrovalvola Gas Nc 1 12 Filettata Available 4 Pz
Elettrovalvola Per Gas Nc 1 1/2” Filettata Omologata In Classe “a” Alimentazione 230v C.a. +/-10% Normalmente Chiusa Riarmo Automatico Max 5000 Mbar. Dotata Di Connettore Elettrico Perry 1evev008
Perry-1EVEV010Gas Solenoid Valve Nc Dn 65 Flanged Available 5 Pz
Gas Solenoid Valve Nc Dn 65 Flanged Approved In Class \"a\" Power Supply 230v Ac Normally Closed Automatic Reset Max 5000 Mbar. Equipped With Electrical Connector Perry 1evevev010
Perry-1EVEV021Elettrovalvola Per Gas Na 34 Filettata Available 10 Pz
Elettrovalvola Per Gas Na 3/4” Filettata Omologata In Classe “a” Alimentazione 230v C.a. +/-10% Normalmente Aperta Riarmo Manuale Max 5000 Mbar. Dotata Di Connettore Elettrico Perry 1evev021
Perry-1EVEV040Solenoid Valve For Gas Nc 12 Threaded Available 3 Pz
Elettrovalvola Per Gas Nc 1/2” Filettata Omologata In Classe “a” Alimentazione 230v C.a. +/-10% Normalmente Chiusa Riarmo Manuale Max 5000 Mbar. Dotata Di Connettore Elettrico Perry 1evev040
Perry-1EVEV041Solenoid Valve For Gas Nc 34 Threaded Available 3 Pz
Elettrovalvola Per Gas Nc 3/4” Filettata Omologata In Classe “a” Alimentazione 230v C.a. +/-10% Normalmente Chiusa Riarmo Manuale Max 5000 Mbar. Dotata Di Connettore Elettrico Perry 1evev041
Perry-1GA4100GPLPerry Lpg Gas Sensor 1ga4100gpl Available 2 Pz
Lpg Sensor Perry 1ga 4100gpl Ip44 Catalytic Sensor For Lpg Gas With a Life Of 5 Years Max. Control Unit Distance 100m Self-extinguishing Abs Material Operating Temperature Limit -10°c _40°c Led Power Supply Signaling
Perry-1GA4200GPLPerry Lpg Gas Sensor 1ga4200gpl Available 2 Pz
Perry 1ga 4200gpl Lpg Sensor For Lpg Gas Ip55 Microprocessor Probe With Self-diagnosis And Automatic Calibration To Adapt To Harsh Environments And Variable Temperatures To Avoid False Alarms Due To Abnormal Events
Perry-1GA47917GPL-PLpg Gas Detector For Wall Perry Available 50 Pz
Perry 1ga 43917gpl/p Wall And/or Semi-recessed Lpg Gas Detector With Zefiro Series Bus Output Microprocessor With Smoke Selection Programme To Prevent False Alarms And Microprocessor With Timer To Signal Revision Recognition Of Remote Sensors
Perry-1GA47917MET-PRilevatore Gas Metano Perry1ga47917metp Available 110 Pz
Perry 1ga 43917met/p Zefiro Wall And/or Semi-recessed Methane Gas Detector With Bus Output Microprocessor With Smoke Selection Program To Prevent False Alarms And Microprocessor With Timer To Signal Revision Recognition Of Remote Sensors
Perry-1GA48917GPL-PPerry 1ga48917gplp Lpg Gas Detector Available 8 Pz
Perry 1ga 48917gpl/p With Zefiro Series Bus Input Microprocessor With Smoke Selection Program To Prevent False Alarms And Microprocessor With Timer To Signal Revision Self-diagnosis Test
Perry-1GA48917MET-PGas Detector Methane Perry Available 8 Pz
Perry 1ga 48917met/p Zefiro Gas Detector With Bus Input Microprocessor With Smoke Selection Program To Prevent False Alarms And Microprocessor With Timer To Signal Revision Self-diagnosis Test
Perry-1GA50916-CHCOGas Detector Wall Perry1ga50916chco Available 9 Pz
Rivelatore Gas Da Parete Perry 1ga 50916/chco Possibilità Di Rilevare Gas Metano Ch4 e Monossido Di Carbonio Co Sensibilità Di Intervento Per Metano Al 10% Del Limite Inferiore Di Esplosività e Per Monossido Carbonio Oltre Max. Concentrazione Ammissibile
Perry-1GA50916-COPerry Carbon Monoxide Detector Available 2 Pz
Rivelatore gas da parete Perry 1GA 50916/CO per Monossido di Carbonio CO Sensibilità di intervento quando viene superata la massima concentrazione di CO ammissibile, 300 ppm, oppure se persistono per lunghi periodi concentrazioni dannose, 30 ppm per 2 ore
Perry-1GA50917GPL-12Gas Detector With Solenoid Valve Kit Available 4 Pz
Kit Methane Gas Detector For Wall Mounting With Na 1/2\" Solenoid Valve Gas Alarm Lpg For Wall Mounting Perry 1ga 50917gpl/1.2 Kit Consisting Of 1 Lpg Gas Detector For Wall Mounting And/or Semi-recessed Mounting \"zefiro\" Series Perry 1ga 50917gpl/p And
MPCSHOP.IT is part of
Circuito Mpc Shop | M.P.C. Musso Personal Computer srl - All rights reserved, The reproduction even partial is forbidden| VAT IT 11811400156 |
Html Site Map Mpcshop |
For information and phone orders: +39 0221117815 | Monday-Friday | 9.00 AM - 1.00PM/2.00PM - 6.00PM GMYT +1 | Fax +39 02700520906 |