The best electro-supply items, for both domestic and industrial use. Made in Italy, excellent materials, items always available and delivered within 48 hours of ordering. Lowest prices online!
Perry Perry 1ga48917gplp Lpg Gas Detector Perry-1GA48917GPL-P
Perry 1ga 48917gpl/p With Zefiro Series Bus Input Microprocessor With Smoke Selection Program To Prevent False Alarms And Microprocessor With Timer To Signal Revision Self-diagnosis Test
LPG GAS INDICATOR ZEPHYR WALL
Price List
Eur. 141,78
Price MPCshop
Eur. 138,03
Available
8 Pcs Estimated Delivery in 5 working days
All prices are VAT included
Bullet points Perry Perry-1GA48917GPL-P
Self-diagnosis
Alarm memory
3 reporting levels
Microprocessor with smoke selection program to avoid false alarms
85dB 1m signal buzzer LED indication ON LED failure indication LED gas concentration on 3 signaling levels
Lpg Gas Warning Device Perry1ga48917gplp Zefiro Series Bus Input From The Wall With Smoke Selection Program To Prevent False Alarms And Microprocessor With Timer To Signal Revision
Customers Reviews Perry Perry-1GA48917GPL-P
Wall and/or semi-recessed LPG gas detector Perry 1GA 48917GPL/P with BUS input ZEFIRO series Microprocessor with smoke selection program to avoid false alarms and microprocessor with timer to signal revision Self-diagnosis test
Wall and/or semi-recessed LPG gas detector with "ZEFIRO" series BUS output, can be set to three different signaling levels, LED indication ON/AVaria/Gas-concept
Main technical innovations: - Device equipped with a microprocessor control circuit with self-diagnosis tasks that ensures the perfect efficiency of the sensor over time. - Sensor equipped with a special selective filter to avoid alarms due to the presence of gas vapours not to be detected, such as kitchen vapours, liquid vapours for cleaning, etc. - Appliances equipped with an operating time counter, in order to signal the necessary replacement of the product after 5 years from its connection. - LEDs to indicate the progressive concentration of gas in the environment. Light and acoustic alarm signal at a gas concentration in the air well below the lower explosion limit (L.I.E.). - TEST system to verify the correct functioning of the device. - The signalers are equipped with a BUS system for application as a peripheral unit connected to a main unit - for the overall protection of the individual house and the entire building.
TECHNICAL CHARACTERISTICS Power supply 230V c.c. 50-60Hz Microprocessor with smoke selection program to prevent false alarms Microprocessor with timer to signal product revision every 5 years Digital BUS input Alarm memory On/OFF switch Self-diagnosis test Voltage buzzer 85dB to 1 m LED ON indication LED failure indication LED gas concentration on 3 signaling levels Operating level 1860 ppm 10IE Wall mounting IP42 Dimensions (WxDxH) 120 x 40 x 82 mm Semi-recessed mounting with accessory IP40 Dimensions (WxDxH) 120 x 27.5 x 82 mm
Wall mounted LPG gas detector BUS inlet ZEFIRO series Perry 1GA48917GPL/P
Perry 1ga48917gplp Lpg Gas Detector Perry-1GA48917GPL-P
Perry 1ga 48917gpl/p With Zefiro Series Bus Input Microprocessor With Smoke Selection Program To Prevent False Alarms And Microprocessor With Timer To Signal Revision Self-diagnosis Test
LPG GAS INDICATOR ZEPHYR WALL
Price List
Eur. 141,78
Price MPCshop
Eur. 138,03
Available
8 Pcs Estimated Delivery in 5 working days
All prices are VAT included
Bullet points Perry Perry-1GA48917GPL-P
Self-diagnosis
Alarm memory
3 reporting levels
Microprocessor with smoke selection program to avoid false alarms
85dB 1m signal buzzer LED indication ON LED failure indication LED gas concentration on 3 signaling levels
Segnalatore di gas GPL da parete e/o semincasso Perry 1GA 48917GPL/P con ingresso BUS serie ZEFIRO Microprocessore con programma selezione fumi per evitare falsi allarmi e microprocessore con timer per segnalazione revisione Test di autodiagnosi
Rilevatore di gas GPL da parete e/o semincasso con uscita BUS serie “ZEFIRO”, impostabile su tre differenti livelli di segnalazione, LED di indicazione ON/Avaria/Concetrazione gas
Principali innovazioni tecniche: • Apparecchio dotato di circuito di controllo a microprocessore con compiti di autodiagnosi che assicura la perfetta efficienza del sensore nel tempo. • Sensore provvisto di un particolare filtro selettivo per evitare allarmi dovuti a presenza di vapori di gas da non rilevare, come vapori di cucina, vapori di liquidi per la pulizia ecc. • Apparecchi dotati di contatore del tempo di funzionamento, al fine di segnalare la necessaria sostituzione del prodotto dopo 5 anni dal suo allacciamento. • LEDs di segnalazione della progressiva concentrazione di gas in ambiente. Segnalazione luminosa e acustica di allarme ad una concentrazione di gas nell’aria molto al di sotto del limite inferiore di esplosività (L.I.E.). • Sistema di TEST per verificare il corretto funzionamento dell’apparecchio. • I segnalatori sono dotati di un sistema BUS per applicazione come unità periferica collegata ad una unità principale - per la protezione globale della singola abitazione e dell'intero edificio.
CARATTERISTICHE TECNICHE Alimentazione 230V c.a. 50-60Hz Microprocessore con programma selezione fumi per evitare falsi allarmi Microprocessore con timer per segnalazione revisione prodotto ogni 5 anni Ingresso BUS digitale Memoria di allarme Selettore ON / TEST Test di autodiagnosi Buzzer di segnalazione 85dB a 1 m LED indicazione ON LED indicazione avaria LED concentrazione gas su 3 livelli di segnalazione Livello di intervento 1860 ppm 10% LIE Montaggio a parete IP42 Dimensioni (LxPxH) 120 x 40 x 82 mm Montaggio a semincasso con accessorio IP40 Dimensioni (LxPxH) 120 x 27.5 x 82 mm
Wall mounted LPG gas detector BUS inlet ZEFIRO series Perry 1GA48917GPL/P
Perry-1GA50917MET-P Rilevatore Gas Metano Perry1ga50917metp
Gas Detector Methane Wall And/or Semi-recessed Perry 1ga50917met/p Zefiro Gas Alarm With Alarm Tripping Signal Buzzer 85db At 1 m Led Indication On Failure And Gas Presence Output 1 Contact In Deflection Tripping Level 5000 Ppm 10ie
Perry-1GA50917GPL-P Lpg Gas Detector For Wall Perry
Lpg Gas Detector For Wall And/or Semi-recessed Installation Perry 1ga50917gpl/p Zefiro Gas Alarm With Signal Buzzer 85 Db At 1 Meter Led Indication On, Failure And Gas Presence Output 1 Contact In Travel Level Of Intervention 1860 Ppm 10ie
Perry-1GA50917MET-12 Methane Gas Detector With Solenoid Valve
Kit Rilevatore Gas Metano Da Parete Con Elettrovalvola Na Da 1/2” Gas Alarm Metano Da Parete Perry 1ga 50917met/1.2 Kit Composto Da 1 Rilevatore Perry 1ga 50917met/p e 1 Elettrovalvola Perry-1evev020
Perry-1GA50917GPL-12 Gas Detector With Solenoid Valve Kit
Kit Methane Gas Detector For Wall Mounting With Na 1/2\" Solenoid Valve Gas Alarm Lpg For Wall Mounting Perry 1ga 50917gpl/1.2 Kit Consisting Of 1 Lpg Gas Detector For Wall Mounting And/or Semi-recessed Mounting \"zefiro\" Series Perry 1ga 50917gpl/p And
Perry-1GA50917MET-34 Methane Gas Detector With Solenoid Valve
Kit Rilevatore Gas Metano Da Parete Con Elettrovalvola Na Da 3/4” Gas Alarm Metano Da Parete Perry 1ga 50917met/3.4 Kit Composto Da 1 Rilevatore Perry 1ga 50917met/p e 1 Elettrovalvola Perry-1evev021
Perry-1GA50917GPL-34 Lpg Gas Detector With Solenoid Valve
Kit Rilevatore Gas Metano Da Parete Con Elettrovalvola Na Da 3/4” Gas Alarm Gpl Da Parete Perry 1ga 50917gpl-34 Kit Composto Da 1 Rilevatore Di Gas Gpl Da Parete E/o Semincasso Serie “zefiro” Perry 1ga 50917gpl/3.4 e 1 Elettrovalvola Perry 1ev Ev021
Perry-1GA51917MET-P Gas Detector Perry 1ga51917metp
Gas Detector Methane Wall And/or Semi-recessed Perry 1ga51917met/p Zefiro Gas Alarm With Signal Buzzer 85 Db At 1 Meter Led Indication On, Failure And Gas Presence Level Of Intervention 5000 Ppm 10ie
Perry-1GA51917GPL-P Perry Lpg Gas Detector 1ga51917gplp
Lpg Gas Detector For Wall And/or Semi-recessed Installation Perry 1ga51917gpl/p Zefiro Gas Alarm With 85 Db Signal Buzzer At 1 Metre Led Indication On, Failure And Gas Presence Intervention Level 1860 Ppm 10ie
Perry-1GA47917MET-P Rilevatore Gas Metano Perry1ga47917metp
Perry 1ga 43917met/p Zefiro Wall And/or Semi-recessed Methane Gas Detector With Bus Output Microprocessor With Smoke Selection Program To Prevent False Alarms And Microprocessor With Timer To Signal Revision Recognition Of Remote Sensors
Perry-1GA47917GPL-P Lpg Gas Detector For Wall Perry
Perry 1ga 43917gpl/p Wall And/or Semi-recessed Lpg Gas Detector With Zefiro Series Bus Output Microprocessor With Smoke Selection Programme To Prevent False Alarms And Microprocessor With Timer To Signal Revision Recognition Of Remote Sensors
Perry 1ga 48917met/p Zefiro Gas Detector With Bus Input Microprocessor With Smoke Selection Program To Prevent False Alarms And Microprocessor With Timer To Signal Revision Self-diagnosis Test
Perry-1GA50916-CHCO Gas Detector Wall Perry1ga50916chco
Rivelatore Gas Da Parete Perry 1ga 50916/chco Possibilità Di Rilevare Gas Metano Ch4 e Monossido Di Carbonio Co Sensibilità Di Intervento Per Metano Al 10% Del Limite Inferiore Di Esplosività e Per Monossido Carbonio Oltre Max. Concentrazione Ammissibile
Rivelatore gas da parete Perry 1GA 50916/CO per Monossido di Carbonio CO Sensibilità di intervento quando viene superata la massima concentrazione di CO ammissibile, 300 ppm, oppure se persistono per lunghi periodi concentrazioni dannose, 30 ppm per 2 ore
Perry-1GA50917MET-P Rilevatore Gas Metano Perry1ga50917metp
Gas Detector Methane Wall And/or Semi-recessed Perry 1ga50917met/p Zefiro Gas Alarm With Alarm Tripping Signal Buzzer 85db At 1 m Led Indication On Failure And Gas Presence Output 1 Contact In Deflection Tripping Level 5000 Ppm 10ie
Perry-1GA50917GPL-P Lpg Gas Detector For Wall Perry
Lpg Gas Detector For Wall And/or Semi-recessed Installation Perry 1ga50917gpl/p Zefiro Gas Alarm With Signal Buzzer 85 Db At 1 Meter Led Indication On, Failure And Gas Presence Output 1 Contact In Travel Level Of Intervention 1860 Ppm 10ie
Perry-1GA50917MET-12 Methane Gas Detector With Solenoid Valve
Kit Rilevatore Gas Metano Da Parete Con Elettrovalvola Na Da 1/2” Gas Alarm Metano Da Parete Perry 1ga 50917met/1.2 Kit Composto Da 1 Rilevatore Perry 1ga 50917met/p e 1 Elettrovalvola Perry-1evev020
Perry-1GA50917GPL-12 Gas Detector With Solenoid Valve Kit
Kit Methane Gas Detector For Wall Mounting With Na 1/2\" Solenoid Valve Gas Alarm Lpg For Wall Mounting Perry 1ga 50917gpl/1.2 Kit Consisting Of 1 Lpg Gas Detector For Wall Mounting And/or Semi-recessed Mounting \"zefiro\" Series Perry 1ga 50917gpl/p And
Perry-1GA50917MET-34 Methane Gas Detector With Solenoid Valve
Kit Rilevatore Gas Metano Da Parete Con Elettrovalvola Na Da 3/4” Gas Alarm Metano Da Parete Perry 1ga 50917met/3.4 Kit Composto Da 1 Rilevatore Perry 1ga 50917met/p e 1 Elettrovalvola Perry-1evev021
Perry-1GA50917GPL-34 Lpg Gas Detector With Solenoid Valve
Kit Rilevatore Gas Metano Da Parete Con Elettrovalvola Na Da 3/4” Gas Alarm Gpl Da Parete Perry 1ga 50917gpl-34 Kit Composto Da 1 Rilevatore Di Gas Gpl Da Parete E/o Semincasso Serie “zefiro” Perry 1ga 50917gpl/3.4 e 1 Elettrovalvola Perry 1ev Ev021
Perry-1GA51917MET-P Gas Detector Perry 1ga51917metp
Gas Detector Methane Wall And/or Semi-recessed Perry 1ga51917met/p Zefiro Gas Alarm With Signal Buzzer 85 Db At 1 Meter Led Indication On, Failure And Gas Presence Level Of Intervention 5000 Ppm 10ie
Perry-1GA51917GPL-P Perry Lpg Gas Detector 1ga51917gplp
Lpg Gas Detector For Wall And/or Semi-recessed Installation Perry 1ga51917gpl/p Zefiro Gas Alarm With 85 Db Signal Buzzer At 1 Metre Led Indication On, Failure And Gas Presence Intervention Level 1860 Ppm 10ie
Perry-1GA47917MET-P Rilevatore Gas Metano Perry1ga47917metp
Perry 1ga 43917met/p Zefiro Wall And/or Semi-recessed Methane Gas Detector With Bus Output Microprocessor With Smoke Selection Program To Prevent False Alarms And Microprocessor With Timer To Signal Revision Recognition Of Remote Sensors
Perry-1GA47917GPL-P Lpg Gas Detector For Wall Perry
Perry 1ga 43917gpl/p Wall And/or Semi-recessed Lpg Gas Detector With Zefiro Series Bus Output Microprocessor With Smoke Selection Programme To Prevent False Alarms And Microprocessor With Timer To Signal Revision Recognition Of Remote Sensors
Perry 1ga 48917met/p Zefiro Gas Detector With Bus Input Microprocessor With Smoke Selection Program To Prevent False Alarms And Microprocessor With Timer To Signal Revision Self-diagnosis Test
Perry-1GA50916-CHCO Gas Detector Wall Perry1ga50916chco
Rivelatore Gas Da Parete Perry 1ga 50916/chco Possibilità Di Rilevare Gas Metano Ch4 e Monossido Di Carbonio Co Sensibilità Di Intervento Per Metano Al 10% Del Limite Inferiore Di Esplosività e Per Monossido Carbonio Oltre Max. Concentrazione Ammissibile
Rivelatore gas da parete Perry 1GA 50916/CO per Monossido di Carbonio CO Sensibilità di intervento quando viene superata la massima concentrazione di CO ammissibile, 300 ppm, oppure se persistono per lunghi periodi concentrazioni dannose, 30 ppm per 2 ore
Perry-1GA48917GPL-PPerry Perry 1ga48917gplp Lpg Gas Detector Perry 1ga 48917gpl/p With Zefiro Series Bus Input Microprocessor With Smoke Selection Program To Prevent False Alarms And Microprocessor With Timer To Signal Revision Self-diagnosis Test white
MPCSHOP.IT is part of
Circuito Mpc Shop | M.P.C. Musso Personal Computer srl - All rights reserved, The reproduction even partial is forbidden| VAT IT 11811400156 |
Html Site Map Mpcshop |
For information and phone orders: +39 0221117815 | Monday-Friday | 9.00 AM - 1.00PM/2.00PM - 6.00PM GMYT +1 | Fax +39 02700520906 |